Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Phase
Three Phase
Washdown Duty
No
Mounting
Foot Mounted
Poles
4
Model
XEX
Voltage
460
Service Factor
1.15
Motor Shaft Length
5 7/8 in
C Face Kit
14-1704
Epact Nominal Full Load Efficiency
93.6 %
Useable at 208V
No
Full Load Pf
86
Full Load Efficiency
95 %
Drive End Bearing
6313
Efficiency Group
Standard Efficient
Frame Material
Cast Iron
Product Line
RG
Mult. Sym.
L1
Frame
364T
Full Load Amps
69
RPM
1800 rpm
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Open End Bearing
6312
RefPicture
ECP03
Voltage Rating
460
Mounting Style
F-1
HP [Min]
60
Design
B
Substitute Motor
CP4314T-4
Frame Size
364T
Enclosure
Totally Enclosed
Rotation
R
Motor Shaft Size
2 3/8 in
Brake Feature
No
Type
1462M
Hz
60 Hz
Motor Application
Severe Duty
Full Load rpm
1780 rpm
VoltCode
G
C Dimension
32.56 in
Weight
941.0 LB
EAN or UPC
781568107591
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back