Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Shaft Size
2 7/8 in
Phase
Three Phase
Mounting
Foot Mounted
HP [Min]
100
C Face Kit
16-1704
Full Load rpm
1780 rpm
Mult. Sym.
LS
Full Load Amps
109
Motor Application
Severe Duty
Voltage
460
Full Load Pf
90
Design
B
Open End Bearing
6313
Washdown Duty
No
Enclosure
Totally Enclosed
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Rotation
R
Mounting Style
F-1
Motor Shaft Length
7 1/4 in
Hz
60 Hz
Brake Feature
No
Frame Size
405T
Useable at 208V
No
Poles
4
Epact Nominal Full Load Efficiency
94.5 %
Voltage Rating
460
Service Factor
1.15
Product Line
RG
Frame Material
Cast Iron
Model
XEX
RPM
1800 rpm
Drive End Bearing
6316
Type
1684M
Substitute Motor
CP4400T-4
C Dimension
36.88 in
Full Load Efficiency
95.4 %
RefPicture
CRUSH
Efficiency Group
Standard Efficient
Frame
405T
VoltCode
G
Weight
1296.0 LB
EAN or UPC
781568107676
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back