Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Rotation
R
Frame Material
Cast Iron
Open End Bearing
6311
Motor Application
Severe Duty
Motor Shaft Size
2 1/8 in
VoltCode
G
Epact Nominal Full Load Efficiency
93 %
Model
841 XL
Enclosure
Totally Enclosed
Service Factor
1.15
Brake Feature
No
C Dimension
30.16 in
Frame
324T
Frame Size
324T
Design
B
Mult. Sym.
L1
Drive End Bearing
6312
Voltage
460
Poles
4
Full Load Amps
46
RPM
1800 rpm
Full Load Pf
86
C Face Kit
12-1105
Washdown Duty
No
Type
1260M
Useable at 208V
No
HP [Min]
40
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Efficiency Group
Standard Efficient
Phase
Three Phase
Hz
60 Hz
Mounting Style
F-1
RefPicture
ECP03
Voltage Rating
460
Full Load Efficiency
94.5 %
Mounting
Foot Mounted
Motor Shaft Length
5 1/4 in
Product Line
RG
Full Load rpm
1775 rpm
Weight
658.0 LB
EAN or UPC
781568196649
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back