Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Efficiency Group
Premium Efficient
Drive End Bearing
6309
Type
3944M
Motor Shaft Length
4 in
Design
B
Mounting Style
F-1
Full Load Pf
86
Enclosure Designation
OPSB - Open Slotted Band
Full Load rpm
1765 rpm
Open End Bearing
6208
Mounting
Rigid Base
Substitute Motor
M2515T
Washdown Duty
No
Full Load Amps
23.5
Useable at 208V
Yes
C Face Kit
39-1400
Poles
4
Motor Shaft Size
1 5/8 in
RPM
1800 rpm
Rotation
R
RefPicture
EMDP
Product Line
RG
Enclosure
OPSB
Brake Feature
No
Frame Size
Shaft Input, Not a C-Face
Motor Application
General Purpose
Voltage Rating
460, 230
VoltCode
E1
Hz
60 Hz
Phase
Three Phase
Full Load Efficiency
93 %
Frame
256T
Epact Nominal Full Load Efficiency
91 %
Frame Material
Steel
Voltage
230/460
Mult. Sym.
L1
Service Factor
1.15
BALD Family Names
Premium Efficient, Nema Premium™
Weight
225.0 LB
EAN or UPC
781568104910
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back