Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Service Factor
1.15
Washdown Duty
No
Design
B
Enclosure
OPSB
RefPicture
EMDP
Frame Size
Shaft Input, Not a C-Face
C Face Kit
40-1400
Voltage Rating
460, 230
RPM
1800 rpm
Mounting Style
F-1
Motor Shaft Size
1 7/8 in
Rotation
R
Motor Application
General Purpose
C Dimension
25.06 in
Mult. Sym.
L1
BALD Family Names
Premium Efficient, Nema Premium™
Frame
286T
Full Load Amps
35
Voltage
230/460
Type
4052M
Motor Shaft Length
4 5/8 in
Full Load rpm
1770 rpm
Phase
Three Phase
Hz
60 Hz
Substitute Motor
M2535T
Product Line
RG
Epact Nominal Full Load Efficiency
92.4 %
Useable at 208V
Yes
Full Load Efficiency
94.1 %
Efficiency Group
Premium Efficient
Full Load Pf
85
Enclosure Designation
OPSB - Open Slotted Band
Brake Feature
No
Poles
4
Drive End Bearing
6311
Open End Bearing
6309
VoltCode
E1
Frame Material
Steel
Mounting
Rigid Base
Weight
372.0 LB
EAN or UPC
781568105054
NEMA Premium
My Applied Catalog