Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
RPM
1200 rpm
Motor Shaft Length
5 1/4 in
Frame
324T
VoltCode
F
Epact Nominal Full Load Efficiency
91.7 %
Mult. Sym.
L1
Design
A
Washdown Duty
No
Motor Application
General Purpose
Full Load Amps
32
Product Line
RG
Full Load rpm
1180 rpm
C Face Kit
12-1105
BALD Family Names
Premium Efficient, Nema Premium™
Brake Feature
No
Type
1080M
Frame Material
Cast Iron
Efficiency Group
Premium Efficient
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Service Factor
1.15
Voltage
230/460
C Dimension
30.28 in
Substitute Motor
M4111T
Useable at 208V
No
Full Load Pf
79
Full Load Efficiency
93 %
Motor Shaft Size
2 1/8 in
Mounting Style
F-1
Rotation
R
Mounting
Rigid Base
Hz
60 Hz
Phase
Three Phase
Frame Size
Shaft Input, Not a C-Face
Poles
6
Enclosure
TEFC
Voltage Rating
460, 230
Open End Bearing
6309
Drive End Bearing
6312
RefPicture
EMTECI
Weight
504.0 LB
EAN or UPC
781568103258