Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Hz
60 Hz, 50 Hz
Mounting Style
F-1
Brake Feature
No
Full Load Efficiency
91.7 %
Full Load Pf
80
RPM
1800 rpm, 1500 rpm
Type
X0740M
Useable at 208V
No
Frame Size
Shaft Input, Not a C-Face
Rotation
R
Motor Application
Explosion Proof
Full Load Amps
9
Voltage Rating
190, 460, 230, 380
Product Line
RG
Poles
4
Mounting
Rigid Base
RefPicture
EM7064T
Drive End Bearing
6307
Service Factor
1
Open End Bearing
6206
C Dimension
19.91 in
Washdown Duty
No
Efficiency Group
Premium Efficient
Motor Shaft Size
1 1/8 in
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Frame
213T
BALD Family Names
Premium Efficient, Explosion Proof
VoltCode
U
Mult. Sym.
L1
Design
A
Enclosure
XPFC
Phase
Three Phase
Voltage
190/380/230/460
Motor Shaft Length
3 in
Full Load rpm
1470 rpm, 1770 rpm
Weight
225.0 LB
EAN or UPC
781568220306
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back