Baldor-Reliance® severe duty motors include features designed to protect against contamination, moisture, vibration and corrosion. These motors use Super-E® premium efficient electrical designs which are built to handle demanding duty cycles, provide high starting and peak torques, and operate over wide speed ranges. Severe Duty motors provide safe, long operating life, reliable performance, and reduced energy consumption in the toughest applications.
applications
Petro-chemical plants
Mines
Foundries
Pulp and Paper plants
Waste management facilities
Chemical plants
Tropical climates
features
Heavy duty cast iron construction
Premium efficient electrical designs
Enhanced ingress protection
Corrosion resistant epoxy finish
caution
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Model
XEX
Enclosure
Totally Enclosed
Frame Material
Cast Iron
Full Load Amps
46
Motor Shaft Size
2 1/8 in
Phase
Three Phase
Design
B
C Face Kit
12-1105
Epact Nominal Full Load Efficiency
93 %
Frame Size
Shaft Input, Not a C-Face
Motor Application
Severe Duty
Motor Shaft Length
5 1/4 in
VoltCode
G
RefPicture
ECP03
C Dimension
30 1/4 in
Hz
60 Hz
Useable at 208V
No
Rotation
R
Full Load rpm
1775 rpm
Product Line
RG
Full Load Efficiency
94.5 %
Type
1260M
Service Factor
1.15
Washdown Duty
No
BALD Family Names
Premium Efficient, Nema Premium™, Severe Duty
Voltage
460
Brake Feature
No
Mounting
Foot Mounted
Open End Bearing
6311
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Drive End Bearing
6312
HP [Min]
40
RPM
1800 rpm
Efficiency Group
Standard Efficient
Poles
4
Frame
324T
Mounting Style
F-1
Mult. Sym.
L1
Full Load Pf
86
Substitute Motor
CP4110T-4
Voltage Rating
460
Weight
659.0 LB
EAN or UPC
781568107508
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back