Baldor-Reliance® severe duty motors include features designed to protect against contamination, moisture, vibration and corrosion. These motors use Super-E® premium efficient electrical designs which are built to handle demanding duty cycles, provide high starting and peak torques, and operate over wide speed ranges. Severe Duty motors provide safe, long operating life, reliable performance, and reduced energy consumption in the toughest applications.
applications
Petro-chemical plants
Mines
Foundries
Pulp and Paper plants
Waste management facilities
Chemical plants
Tropical climates
features
Heavy duty cast iron construction
Premium efficient electrical designs
Enhanced ingress protection
Corrosion resistant epoxy finish
caution
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Efficiency Group
Standard Efficient
VoltCode
G
Product Line
RG
Full Load Efficiency
95.8 %
Epact Nominal Full Load Efficiency
95 %
Frame
447TS
Poles
2
Full Load Amps
220
Motor Application
Severe Duty
Type
1876M
Service Factor
1.15
Hz
60 Hz
Motor Shaft Size
2 3/8 in
Open End Bearing
6313
Voltage Rating
460
Enclosure
Totally Enclosed
BALD Family Names
Premium Efficient, Nema Premium™, Severe Duty
Mounting Style
F-1
Voltage
460
Washdown Duty
No
Rotation
R
Frame Size
Shaft Input, Not a C-Face
Mult. Sym.
D3
Full Load Pf
89
HP [Min]
200
Useable at 208V
No
Drive End Bearing
6313
Phase
Three Phase
RefPicture
CRUSH
Model
XEX
RPM
3600 rpm
Mounting
Foot Mounted
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Frame Material
Cast Iron
Brake Feature
No
C Dimension
43.93 in
Motor Shaft Length
4 3/4 in
Full Load rpm
3570 rpm
Design
B
Weight
2129.0 LB
EAN or UPC
781568107744
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back