Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Service Factor
1.15
Full Load Amps
26
Motor Shaft Length
4 5/8 in
Brake Feature
No
Type
4056M
Useable at 208V
Yes
Mounting
Rigid Base
Motor Application
General Purpose
Substitute Motor
M2528T
Drive End Bearing
6311
RefPicture
EMDP
Frame Size
Shaft Input, Not a C-Face
Open End Bearing
6309
Design
B
Frame
286T
C Face Kit
40-1400
Motor Shaft Size
1 7/8 in
Mult. Sym.
L1
BALD Family Names
Premium Efficient, Nema Premium™
Enclosure Designation
OPSB - Open Slotted Band
Hz
60 Hz
Full Load Efficiency
92.4 %
Phase
Three Phase
Efficiency Group
Premium Efficient
Full Load rpm
1180 rpm
Voltage Rating
460, 230
Washdown Duty
No
RPM
1200 rpm
Frame Material
Steel
Rotation
R
Epact Nominal Full Load Efficiency
91 %
Product Line
RG
VoltCode
E1
Poles
6
Full Load Pf
80
Voltage
230/460
Enclosure
OPSB
Mounting Style
F-1
Weight
372.0 LB
EAN or UPC
781568104941
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back