Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Substitute Motor
M2536T
Washdown Duty
No
Poles
6
RPM
1200 rpm
Voltage Rating
460, 230
Efficiency Group
Premium Efficient
Full Load rpm
1180 rpm
Drive End Bearing
6312
Design
B
Frame
326T
BALD Family Names
Premium Efficient, Nema Premium™
Motor Application
General Purpose
Mounting
Rigid Base
C Face Kit
42-1300
Service Factor
1.15
Enclosure Designation
OPSB - Open Slotted Band
Open End Bearing
6311
Phase
Three Phase
Mult. Sym.
L1
RefPicture
EMDP
C Dimension
27.69 in
Full Load Pf
81
Motor Shaft Size
2 1/8 in
Motor Shaft Length
5 1/4 in
Brake Feature
No
Hz
60 Hz
Voltage
230/460
Frame Material
Steel
Full Load Amps
37
Enclosure
OPSB
Product Line
RG
Rotation
R
Mounting Style
F-1
Frame Size
Shaft Input, Not a C-Face
Epact Nominal Full Load Efficiency
92.4 %
Useable at 208V
Yes
VoltCode
E1
Type
4268M
Full Load Efficiency
93.6 %
Weight
463.0 LB
EAN or UPC
781568105085
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back