Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Design
B
Washdown Duty
No
Service Factor
1.15
Full Load Amps
82
Rotation
R
Poles
2
Motor Application
General Purpose
Voltage Rating
460, 230
Efficiency Group
Premium Efficient
Brake Feature
No
Voltage
230/460
RPM
3600 rpm
Substitute Motor
M2549T
Mounting Style
F-1
Mounting
Rigid Base
Mult. Sym.
L1
C Dimension
27.56 in
Frame Size
Shaft Input, Not a C-Face
RefPicture
ODP3P
Epact Nominal Full Load Efficiency
93 %
Enclosure
OPSB
Useable at 208V
No
Product Line
RG
Enclosure Designation
OPSB - Open Slotted Band
Drive End Bearing
6313
BALD Family Names
Premium Efficient, Nema Premium™
Hz
60 Hz
Full Load Pf
91
Full Load Efficiency
94.5 %
VoltCode
F
Frame Material
Steel
Open End Bearing
6311
Frame
364TS
Type
4254M
Phase
Three Phase
Motor Shaft Size
1 7/8 in
Motor Shaft Length
3 3/4 in
Full Load rpm
3540 rpm
C Face Kit
14-1401
Weight
507.0 LB
EAN or UPC
781568105283
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back