Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Application
General Purpose
Mounting Style
F-1
Product Line
RG
Rotation
R
Open End Bearing
6206
Phase
Three Phase
VoltCode
H
Design
B
Motor Shaft Length
3 in
Enclosure Designation
OPSB - Open Slotted Band
Drive End Bearing
6307
Brake Feature
No
Motor Shaft Size
1 1/8 in
Washdown Duty
No
Poles
4
C Dimension
17.45 in
RefPicture
EMDP
Service Factor
1.15
Full Load Pf
79
Full Load Amps
10.2
Voltage Rating
575
Frame
215T
Frame Size
Shaft Input, Not a C-Face
Mult. Sym.
L1
Mounting
Rigid Base
RPM
1800 rpm
Full Load Efficiency
91.7 %
Type
3746M
Enclosure
OPSB
Hz
60 Hz
Voltage
575
Useable at 208V
No
BALD Family Names
Premium Efficient, Nema Premium™
Substitute Motor
EM3774T-5
Efficiency Group
Premium Efficient
Full Load rpm
1760 rpm
Weight
123.0 LB
EAN or UPC
781568118665
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back