Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Substitute Motor
M3314T
RefPicture
EMDP
Mounting
Rigid Base
Product Line
RG
Drive End Bearing
6307
Rotation
R
Enclosure Designation
OPSB - Open Slotted Band
Service Factor
1.15
Epact Nominal Full Load Efficiency
89.5 %
Voltage
230/460
Type
3744M
Motor Application
General Purpose
Brake Feature
No
Enclosure
OPSB
Useable at 208V
Yes
Frame Material
Steel
VoltCode
E1
Open End Bearing
6206
Frame Size
Shaft Input, Not a C-Face
C Face Kit
37-1404
Hz
60 Hz
Full Load Efficiency
91.7 %
Mult. Sym.
L1
C Dimension
17.44 in
Full Load Amps
17
Full Load rpm
3525 rpm
Frame
215T
Efficiency Group
Premium Efficient
Poles
2
RPM
3600 rpm
Voltage Rating
460, 230
Mounting Style
F-1
Phase
Three Phase
Full Load Pf
92
Washdown Duty
No
Motor Shaft Length
3 3/8 in
Motor Shaft Size
1 3/8 in
BALD Family Names
Premium Efficient, Nema Premium™
Design
B
Weight
124.0 LB
EAN or UPC
781568104828
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back