Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Mounting Style
F-1
Mult. Sym.
L1
Epact Nominal Full Load Efficiency
87.5 %
Poles
6
Frame
213T
Design
B
Rotation
R
Drive End Bearing
6307
BALD Family Names
Premium Efficient, Nema Premium™
Motor Shaft Length
3 3/8 in
Frame Material
Steel
Full Load Efficiency
89.5 %
Voltage
230/460
C Dimension
17.94 in
RPM
1200 rpm
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Open End Bearing
6206
Motor Application
General Purpose
Full Load rpm
1160 rpm
Brake Feature
No
Service Factor
1.15
Efficiency Group
Premium Efficient
Motor Shaft Size
1 3/8 in
RefPicture
EM3708T
Mounting
Rigid Base
Hz
60 Hz
Frame Size
Shaft Input, Not a C-Face
Full Load Amps
5
Phase
Three Phase
Useable at 208V
Yes
Product Line
RG
C Face Kit
37-1304
VoltCode
E1
Enclosure
TEFC
Full Load Pf
64
Washdown Duty
No
Voltage Rating
460, 230
Type
3736M
Weight
134.0 LB
EAN or UPC
781568139011
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back