Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Drive End Bearing
6311
Full Load rpm
1180 rpm
Epact Nominal Full Load Efficiency
90.2 %
Motor Shaft Size
1 7/8 in
Enclosure
TEFC
Brake Feature
No
Mounting
Rigid Base
Frame Material
Cast Iron
Voltage
230/460
Service Factor
1.15
C Dimension
27.76 in
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Motor Application
General Purpose
Open End Bearing
6309
Product Line
RG
Rotation
R
Phase
Three Phase
RPM
1200 rpm
Design
B
Motor Shaft Length
4 5/8 in
Full Load Amps
18.7
Frame
284T
Full Load Pf
81
Efficiency Group
Premium Efficient
Mounting Style
F-1
Frame Size
Shaft Input, Not a C-Face
Type
1054M
C Face Kit
10-1305
Voltage Rating
460, 230
VoltCode
E1
Poles
6
Useable at 208V
Yes
Full Load Efficiency
92.4 %
BALD Family Names
Premium Efficient, Nema Premium™
Hz
60 Hz
Washdown Duty
No
Substitute Motor
EM4102T
RefPicture
EMTECI
Mult. Sym.
L1
Weight
391.0 LB
EAN or UPC
781568103029
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back