Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Hz
60 Hz
Voltage Rating
575
Useable at 208V
No
Open End Bearing
6311
Frame Size
Shaft Input, Not a C-Face
Full Load Pf
91
VoltCode
H
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Substitute Motor
M4114T-5
RefPicture
EMTECI
Frame Material
Cast Iron
Washdown Duty
No
RPM
3600 rpm
Motor Application
General Purpose
Motor Shaft Length
3 3/4 in
Full Load Amps
43.6
Mounting
Rigid Base
Drive End Bearing
6312
Efficiency Group
Premium Efficient
Design
B
BALD Family Names
Premium Efficient, Nema Premium™
Phase
Three Phase
Full Load Efficiency
94.1 %
Service Factor
1.15
Mult. Sym.
L1
Voltage
575
Type
1252M
Full Load rpm
3540 rpm
Brake Feature
No
Frame
326TS
Rotation
R
Poles
2
C Face Kit
12-1105
C Dimension
28.78 in
Product Line
RG
Motor Shaft Size
1 7/8 in
Mounting Style
F-1
Enclosure
TEFC
Weight
578.0 LB
EAN or UPC
781568139141
NEMA Premium