Vickers D03 Solenoid Valve

02-108045

Vickers D03 Solenoid Valve
Item #101855180
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

compliances

  • 0
Mechanical Options None
Overrides No Overrides
Temperature Range [Max] 158 °F
Pressure [Max] 5000 psi
Seal Material Buna-N
Port T Pressure Rating 3000 psi
Fluid Cleanliness 19/17/14 micron
Spool Code 6
Response Type Standard Response
No. of Stages Single Stage
Electrical Connector Code T
Response Time 28 to 45 ms
NFPA Size D03
Electrical Connection Wired Terminal Block
Coil Rating Code H
Model No. DG4V 3 6C M FTWL H7 60
Port T Code 7
Function 3-Position, 4-Way, Spring Centered
Manual Override Option Code None
Pilot Valve Type N/A
Surge Suppressor/Damper None
Operation Solenoid Operated
Center Position P Blocked, A & B to T
Tank Port Rating 3046
Valve Type High-Performance
Rated Flow 10.6 gal/min
Compatible Fluids Petroleum Oil
Performance High Performance
Body Material Gray Iron
Cycle Rate [Max] N/A
AC/DC DC
Solenoid Indicator Lights Code L
Leakage Standard Performance
Manual Override Plain Override
EN Code None
Function Code 6
Indicator Lights Yes
Mounting Subplate/Manifold Mount
Spool Shift Timing N/A
Actuation Identification Solenoid A, Solenoid B
Port Restrictor Plugs None
Housing Code W
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Actuator Type Solenoid
Electrical Options None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure Port Check Valve Pressure N/A
Solenoid Double
Design No. 60
Temperature Range [Min] -4 °F
Crossover P Blocked, A or B to T
Voltage & Frequency 24 VDC
Pilot/Drain None
Coil Type Code F
Spool Spring Arrangement Code C
Solenoid Code H
Watt Rating 30 W
Surge Suppressor/Damper Code None
Reducer Module No
Manufacturer Part No. DG4V 3 6C M FTWL H7 60
Solenoid Energization Code None
Rated Flow [Max] 20 gal/min
Weight 4.6 LB