Vickers D03 Solenoid Valve

02-109979

Vickers D03 Solenoid Valve
Item #101958067
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
NFPA Size D03
Coil Rating Code HL
Port Restrictor Plug Code None
Electrical Connection DIN 43650
Response Type Standard Response
Watt Rating 18 W
Performance High Performance
Leakage Standard Performance
EN Code None
No. of Stages Single Stage
Overrides No Overrides
Function 2-Position Spring Offset, Left Hand Build
Surge Suppressor/Damper None
Manual Override Plain Override
Electrical Connector Code None
Voltage & Frequency 24 VDC
Pilot Valve Type N/A
Solenoid Energization Code None
AC/DC DC
Rated Flow [Max] 20 gal/min
Design No. 60
Cycle Rate [Max] N/A
Spool Shift Timing N/A
Solenoid Code HL
Manual Override Option Code None
Port Restrictor Plugs None
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Model No. DG4V 3 2AL M U HL7 60
Valve Type High-Performance
Actuator Type Solenoid
Pressure [Max] 5000 psi
Housing Code None
Port T Pressure Rating 3000 psi
Temperature Range [Min] -4 °F
Seal Material Buna-N
Response Time 28 to 45 ms
Mechanical Options None
Mounting Subplate/Manifold Mount
Center Position All Ports Blocked
Electrical Options None
Coil Type ISO 4400
Operation Solenoid Operated
Reducer Module No
Coil Type Code U
Pilot/Drain None
Indicator Lights No
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper Code None
Actuation Identification Solenoid A
Spool Code 2
Solenoid Single
Spool Spring Arrangement Code A
Function Code 2
Temperature Range [Max] 158 °F
Body Material Gray Iron
Crossover All Ports Blocked
Tank Port Rating 3046
Solenoid Indicator Lights Code None
Port T Code 7
Pressure Port Check Valve Pressure N/A
Weight 5.0 LB