Vickers D03 Solenoid Valve

02-110359

Vickers D03 Solenoid Valve
Item #101850840
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Spool Code 6
Seal Material Viton
Response Type Standard Response
Surge Suppressor/Damper Code None
Function 3-Position, 4-Way, Spring Centered
Port Restrictor Plug Code None
Mounting Manifold Mount
Temperature Range [Max] 158 °F
Overrides No Overrides
Tank Port Rating 3046
Electrical Connection Wired Terminal Block
Housing Code W
Coil Type Code F
Coil Rating Code B
Temperature Range [Min] -4 °F
Solenoid Double
Fluid Cleanliness 19/17/14 micron
Spool Shift Timing N/A
Pressure [Max] 5,075 psi
Crossover P Blocked, A or B to T
Spool Indicator Switch Code None
Spool Spring Arrangement Code C
Solenoid Indicator Lights Code L
Reducer Module No
Manufacturer Part No. DG4V 3 6C M FTWL B6 60
Body Material Gray Iron
Manual Override Plain Override
Design No. 60
Performance Standard Performance
Pilot/Drain None
EN Code None
NFPA Size D03
Indicator Lights Yes
Port T Pressure Rating 3000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type N/A
Leakage Standard Performance
Manual Override Option Code None
Compatible Fluids Phosphate Ester Fluids
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port Restrictor Plugs None
Center Position P Blocked, A & B to T
Port T Code 6
Operation Solenoid Operated
Electrical Connector Code T
AC/DC AC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Code B
Valve Type High-Performance
Mechanical Options None
Electrical Options None
Surge Suppressor/Damper None
Rated Flow 21.00 gal/min
Watt Rating 20 W
Rated Flow [Max] 20.00 gal/min
Function Code 6
Actuator Type Solenoid
No. of Stages Single Stage
Cycle Rate [Max] 0
Solenoid Energization Code None
Model No. DG4V36CMFTWLB660
Pressure Port Check Valve Pressure N/A
Weight 4.6 LB