Vickers by Danfoss02-126360

02-126360

Vickers D05 Solenoid Valve
Item #101974088
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function
Vickers by Danfoss02-126360
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Overrides No Overrides
Tank Port Rating 1000
AC/DC AC
Temperature Range [Max] 122 °F
Spool Spring Arrangement Code C
Compatible Fluids Petroleum Oil
Port Restrictor Plugs None
Actuation Identification Solenoid A, Solenoid B
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Coil Type Code U
Reducer Module N/A
Temperature Range [Min] 68 °F
Pressure [Max] 5000 psi
Pressure Port Check Valve Pressure N/A
Manual Override Plain Override
Leakage Standard Performance
Electrical Connection DIN 43650
Response Type Standard Response
Electrical Options None
Design No. 60
Mounting Subplate/Manifold Mount
Voltage & Frequency 220/240 VAC - 50/60 Hz
Mechanical Options None
Electrical Options Code None
Body Material Gray Iron
Coil Rating Code D
Valve Type Standard-Duty
Performance Standard Performance
NFPA Size D05
Solenoid Double
Operation Solenoid Operated
Port T Pressure Rating 1000 psi
Rated Flow [Max] 24 gal/min
Coil Type ISO 4400 (Din 43650) Connector
Pilot Valve Type N/A
No. of Stages Single Stage
Response Time 20 to 40 ms
Function 3-Position Spring Centered, Double End
Model No. DG4S4-016C-U-D-60
Actuator Type Solenoid
Cycle Rate [Max] N/A
Center Position P Blocked, A & B to T
Crossover P Blocked, A or B to T
Indicator Lights No
Pilot/Drain None
Flow Direction Code 4
Seal Material Buna-N
Mechanical Options Code None
Spool Code 6
Weight 10.0 LB