Skip to content Skip to navigation menu
Vickers by Danfoss02-126373

02-126373

Vickers D05 Solenoid Valve
Item #101957567
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-126373
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Design No. 60
Seal Material Buna-N
Watt Rating 30 W
Pressure Port Check Valve Pressure N/A
Mechanical Options Code None
Electrical Connection DIN 43650
Indicator Lights No
Rated Flow [Max] 24 gal/min
Tank Port Rating 1000
Response Time 50 to 80 ms
Mounting Subplate/Manifold Mount
Coil Type ISO 4400
Body Material Gray Iron
Response Type Standard Response
Cycle Rate [Max] N/A
Actuator Type Solenoid
Actuation Identification Solenoid A, Solenoid B
AC/DC DC
Valve Type Standard-Duty
Overrides No Overrides
Operation Solenoid Operated
NFPA Size D05
Spool Code 33
Temperature Range [Min] 68 °F
Leakage Standard Performance
Compatible Fluids Petroleum Oil
Port T Pressure Rating 1000 psi
Crossover P Blocked, A or B to T
Port Restrictor Plugs None
Performance Standard Performance
Model No. DG4S4-0133C-U-H-60
Center Position P Blocked, A & B to T
Reducer Module N/A
Temperature Range [Max] 122 °F
Surge Suppressor/Damper None
Pilot/Drain None
Flow Direction Code 4
Pilot Valve Type N/A
Electrical Options Code None
Mechanical Options None
Electrical Options None
Coil Rating Code H
Spool Spring Arrangement Code C
Voltage & Frequency 24 VDC
Manual Override Plain Override
No. of Stages Single Stage
Pressure [Max] 5000 psi
Solenoid Double
Coil Type Code U
Fluid Cleanliness 19/17/14 micron
Function 3-Position Spring Centered
Weight 10.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison