Skip to content Skip to navigation menu
Vickers by Danfoss02-126387

02-126387

Vickers D05 Solenoid Valve
Item #101954694
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-126387
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Valve Type Standard-Duty
Coil Type Code U
Temperature Range [Min] 68 °F
Port Restrictor Plugs None
Mechanical Options Code None
Function 3-Position Spring Centered
Mechanical Options None
Port T Pressure Rating 1000 psi
Actuation Identification Solenoid A, Solenoid B
Spool Code 1
Pressure Port Check Valve Pressure N/A
Performance Standard Performance
Center Position P to A & T, B Blocked
Fluid Cleanliness 19/17/14 micron
Crossover All Ports Open
NFPA Size D05
Leakage Standard Performance
Electrical Options Code None
Temperature Range [Max] 122 °F
Body Material Gray Iron
Design No. 60
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Mounting Subplate/Manifold Mount
No. of Stages Single Stage
AC/DC AC
Flow Direction Code 4
Model No. DG4S4-011C-U-D-60
Electrical Connection DIN 43650
Cycle Rate [Max] N/A
Manual Override Plain Override
Seal Material Buna-N
Response Time 20 to 40 ms
Overrides No Overrides
Pilot/Drain None
Indicator Lights No
Surge Suppressor/Damper None
Electrical Options None
Solenoid Double
Pressure [Max] 5000 psi
Coil Type ISO 4400
Reducer Module N/A
Actuator Type Solenoid
Voltage & Frequency 220/240 VAC - 50/60 Hz
Spool Spring Arrangement Code C
Response Type Standard Response
Operation Solenoid Operated
Tank Port Rating 1000
Coil Rating Code D
Rated Flow [Max] 24 gal/min
Weight 10.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison