Vickers by Danfoss02-126583

02-126583

Vickers D05 Solenoid Valve
Item #101967582
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function
Vickers by Danfoss02-126583
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Rated Flow [Max] 24 gal/min
Cycle Rate [Max] N/A
Performance Standard Performance
Coil Type ISO 4400 (Din 43650) Connector
Design No. 60
Pressure [Max] 5000 psi
Center Position P to A & B, T Blocked
Body Material Gray Iron
Solenoid Double
Leakage Standard Performance
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Tank Port Rating 1000
Spool Spring Arrangement Code C
Operation Solenoid Operated
NFPA Size D05
Indicator Lights No
Actuation Identification Solenoid A, Solenoid B
Mechanical Options Code None
Mechanical Options None
Port T Pressure Rating 1000 psi
Model No. DG4S4-017C-U-H-60
Flow Direction Code 4
Function 3-Position Spring Centered, Double End
AC/DC DC
Temperature Range [Min] 68 °F
Compatible Fluids Petroleum Oil
Electrical Connection DIN 43650
Valve Type Standard-Duty
Coil Type Code U
Voltage & Frequency 24 VDC
Crossover P to A or B, T & A or B Blocked
Surge Suppressor/Damper None
Electrical Options None
Watt Rating 30 W
Temperature Range [Max] 122 °F
No. of Stages Single Stage
Pilot/Drain None
Seal Material Buna-N
Spool Code 7
Reducer Module N/A
Response Time 50 to 80 ms
Overrides No Overrides
Fluid Cleanliness 19/17/14 micron
Actuator Type Solenoid
Response Type Standard Response
Electrical Options Code None
Manual Override Plain Override
Mounting Subplate/Manifold Mount
Coil Rating Code H
Pilot Valve Type N/A
Weight 10.0 LB