Vickers D07 Solenoid Valve
Item #102041989
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-134879
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Manual Override Plain Override
Manual Override Option Code None
Function 3-Position Spring Centered
Center Position P & A Blocked, B to T
EN Code None
Pressure Port Check Valve Code None
Mounting Subplate/Manifold Mount
Pilot Pressure Code None
Valve Type Standard-Duty
Mounting Screw Option Code N/A
Solenoid Energization Code None
Coil Type 1/2 in NPT Thread Wiring Housing
Tank Port Rating 1450
Fluid Cleanliness 19/17/14 micron
Electrical Options None
AC/DC AC
Model No. DG5S4-0431C-M-FTWL-B5-60
Pilot Drain Code None
Pressure [Max] 3000 psi
Design No. 60
Electrical Options Code None
Electrical Connector Code T
Operation Solenoid Operated
Pressure Port Check Valve Pressure N/A
Housing Code W
Actuator Type Solenoid
Compatible Fluids Petroleum Oil
Solenoid Indicator Lights Code L
Response Type Standard Response
Indicator Lights Yes
Leakage Standard Performance
Pilot/Drain External Drain
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 1450 psi
Coil Type Code F
Response Type Code None
Rated Flow [Max] 60 gal/min
Spool Indicator Switch Code None
Spool Spring Arrangement Code C
Assembly Code None
No. of Stages Two Stage
Pilot Valve Tank Pressure Rating Code 5
Surge Suppressor/Damper None
NFPA Size D07
Performance Standard Performance
Crossover All Ports Blocked
Body Material Gray Iron
Reducer Module N/A
Port Restrictor Plugs None
Pilot Valve Type N/A
Coil Rating Code B
Spool Code 31
Seal Material Buna-N
Spool Control Modification Code None
Overrides Plain Override Solenoid Ends
Mechanical Options None
Electrical Connection Wired Terminal Block
Solenoid Double
Port Restrictor Plug Code None
Weight 15.0 LB