Vickers D03 Solenoid Valve
Item #102054551
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers by Danfoss02-136014
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 2-Position Spring Offset, Left Hand Build
Center Position All Ports Blocked
Surge Suppressor/Damper Code None
Tank Port Rating 1450
EN Code EN21
Pressure [Max] 5000 psi
Manual Override Option Code None
Actuation Identification Solenoid A
NFPA Size D03
Temperature Range [Max] 158 °F
Performance Standard Performance
Port T Pressure Rating 1500 psi
Port Restrictor Plug Code None
Solenoid Code B
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code A
Cycle Rate [Max] N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Leakage Standard Performance
Coil Rating Code B
Compatible Fluids Petroleum Oil
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mounting Subplate/Manifold Mount
Electrical Options None
AC/DC AC
Indicator Lights No
Seal Material Buna-N
Function Code 2
Design No. 60
Surge Suppressor/Damper None
Pilot/Drain None
Fluid Cleanliness 19/17/14 micron
Response Time 18 to 32 ms
Spool Indicator Switch Code None
No. of Stages Single Stage
Spool Code 2
Rated Flow [Max] 10 gal/min
Actuator Type Solenoid
Body Material Gray Iron
Pilot Valve Type N/A
Crossover All Ports Blocked
Solenoid Single
Manual Override Plain Override
Spool Shift Timing N/A
Port T Code 5
Response Type Standard Response
Housing Code W
Overrides No Overrides
Model No. DG4V-3S-2AL-M-FW-B5-60-EN21
Reducer Module No
Electrical Connector Code None
Port Restrictor Plugs None
Solenoid Energization Code None
Pressure Port Check Valve Pressure N/A
Temperature Range [Min] -4 °F
Coil Type Code F
Valve Type Standard-Duty
Operation Solenoid Operated
Electrical Connection No Connector
Mechanical Options None
Weight 5.0 LB