Vickers D03 Solenoid Valve

02-138571

Vickers D03 Solenoid Valve
Item #101994695
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Model No. DG4V 3S 6N M FPBW B5 60
Indicator Lights No
Port T Code 5
Valve Type Standard-Duty
Overrides No Overrides
Seal Material Buna-N
Surge Suppressor/Damper Code None
Crossover P Blocked, A or B to T
Function Code 6
Solenoid Code B
Solenoid Indicator Lights Code None
Manual Override Option Code None
Tank Port Rating 1500
Spool Spring Arrangement Code N
Mechanical Options None
Pressure [Max] 5075 psi
Pilot Valve Type N/A
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Coil Type Code F
Port T Pressure Rating 1500 psi
Spool Indicator Switch Code None
Response Type Standard Response
Solenoid Energization Code None
Operation Solenoid Operated
Pilot/Drain None
Spool Code 6
Electrical Connector Code PB
Center Position P Blocked, A & B to T
Spool Shift Timing N/A
Reducer Module N/A
Rated Flow [Max] 10.5 gal/min
EN Code None
Port Restrictor Plug Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Function 3-Position Detented
Surge Suppressor/Damper None
Solenoid Double
Housing Code W
Cycle Rate [Max] N/A
Design No. 60
AC/DC AC
NFPA Size D03
Electrical Connection Instaplug Male & Female Receptacle
Port Restrictor Plugs None
Electrical Options None
Coil Rating Code B
Weight 5.0 LB