Vickers D03 Solenoid Valve

02-144010

Vickers D03 Solenoid Valve
Item #102085956
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Electrical Connection No Connector
Solenoid Indicator Lights Code None
Port Restrictor Plug Code None
Actuation Identification Solenoid A, Solenoid B
Center Position P Blocked, A & B to T
Spool Shift Timing N/A
Spool Spring Arrangement Code C
Actuator Type Solenoid
Body Material Gray Iron
Coil Type Code F
Solenoid Energization Code None
Surge Suppressor/Damper None
Electrical Options None
Performance High Performance
Voltage & Frequency 220/240 VAC - 50/60 Hz
Spool Code 6
Reducer Module No
Pressure Port Check Valve Pressure N/A
Temperature Range [Max] 158 °F
Coil Rating Code D
Solenoid Double
Solenoid Code D
EN Code EN21
Valve Type High-Performance
Port T Pressure Rating 3000 psi
Pilot/Drain None
Rated Flow [Max] 20 gal/min
Operation Solenoid Operated
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
NFPA Size D03
No. of Stages Single Stage
Port T Code 6
Seal Material Buna-N
Manual Override Option Code None
Manual Override Plain Override
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Temperature Range [Min] -4 °F
Function Code 6
Surge Suppressor/Damper Code None
Function 3-Position Spring Centered
Mechanical Options None
Overrides No Overrides
Crossover P Blocked, A or B to T
Electrical Connector Code None
Indicator Lights No
Tank Port Rating 3046
AC/DC AC
Cycle Rate [Max] N/A
Compatible Fluids Petroleum Oil
Design No. 60
Response Time 15 to 23 ms
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Leakage Standard Performance
Pilot Valve Type N/A
Pressure [Max] 5000 psi
Housing Code W
Model No. DG4V-3-6C-M-FW-D6-60-EN21
Weight 5.0 LB