Vickers D03 Solenoid Valve

02-144958

Vickers D03 Solenoid Valve
Item #102084700
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Crossover All Ports Open, Restricted
Function 3-Position Spring Centered
Coil Type ISO 4400
Rated Flow [Max] 20 gal/min
Mechanical Options None
Spool Spring Arrangement Code C
No. of Stages Single Stage
Pressure [Max] 5000 psi
Temperature Range [Min] -4 °F
Actuator Type Solenoid
Port T Code 7
Performance High Performance
Manual Override Plain Override
Spool Indicator Switch Code None
Spool Shift Timing N/A
Solenoid Indicator Lights Code None
Port Restrictor Plugs None
Function Code 8
Temperature Range [Max] 158 °F
Voltage & Frequency 24 VDC, Low Power Coil
Center Position P to T, A & B Blocked
NFPA Size D03
Compatible Fluids Petroleum Oil
Pilot/Drain None
Surge Suppressor/Damper None
Solenoid Energization Code V
Actuation Identification Solenoid A, Solenoid B
Mounting Subplate/Manifold Mount
Indicator Lights No
Pilot Valve Type N/A
Body Material Gray Iron
Leakage Standard Performance
Seal Material Buna-N
Electrical Options None
EN Code None
Valve Type High-Performance
Coil Type Code U
Spool Code 8
Response Type Standard Response
Solenoid Code HL
Manual Override Option Code None
Solenoid Double
AC/DC DC
Tank Port Rating 3046
Fluid Cleanliness 19/17/14 micron
Housing Code None
Reducer Module No
Port T Pressure Rating 3000 psi
Design No. 61
Coil Rating Code HL
Overrides No Overrides
Pressure Port Check Valve Pressure N/A
Electrical Connector Code None
Port Restrictor Plug Code None
Cycle Rate [Max] N/A
Surge Suppressor/Damper Code None
Operation Solenoid Operated
Electrical Connection DIN 43650
Model No. DG4V-3-8C-VM-U-HL7-61
Weight 5.0 LB