Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-144984

Vickers D03 Solenoid Valve
Item #101855888
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Solenoid Double
Function 3-Position, 4-Way, Spring Centered
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Port Restrictor Plugs None
Solenoid Code B
Leakage Standard Performance
Spool Center Condition A Port and Double Offset sensing switch on B Port
Spool Code 8
No. of Stages Single Stage
Housing Code W
Body Material Gray Iron
AC/DC AC
Temperature Range [Max] 158 °F
Actuation Identification Solenoid A, Solenoid B
EN Code None
Temperature Range [Min] -4 °F
Cycle Rate [Max] 0
Pressure [Max] 5,075 psi
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Spring Arrangement Code C
Indicator Lights Yes
Valve Type High-Performance
Port T Code 6
Watt Rating 20 W
Coil Rating Code B
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
Mounting Manifold Mount
Compatible Fluids Petroleum Oil
Reducer Module No
Performance Standard Performance
Rated Flow 21.00 gal/min
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options None
Seal Material Buna-N
Pilot Valve Type N/A
Design No. 61
Model No. DG4V-3-8C-VM-FTWL-B6-61
Port T Pressure Rating 3000 psi
Mechanical Options None
Operation Solenoid Operated
Response Time 15 to 23 ms
Coil Type Code F
NFPA Size D03
Crossover All Ports Open, Restricted
Rated Flow [Max] 20.00 gal/min
Surge Suppressor/Damper Code None
Function Code 8
Tank Port Rating 3046
Overrides No Overrides
Solenoid Indicator Lights Code L
Solenoid Energization Code V
Manual Override Plain Override
Electrical Connection Wired Terminal Block
Actuator Type Solenoid
Electrical Connector Code T
Center Position P to T, A & B Blocked
Pilot/Drain None
Manufacturer Part No. DG4V 3 8C V M FTWL B6 61
Response Type Standard Response
Spool Shift Timing N/A
Manual Override Option Code None
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison