Vickers D03 Solenoid Valve

02-146146

Vickers D03 Solenoid Valve
Item #102089358
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 3-Position Spring Centered
Coil Rating Code G
Tank Port Rating 3046
Performance High Performance
Function Code 2
Overrides No Overrides
Design No. 60
Pilot Valve Type N/A
Actuator Type Solenoid
Housing Code W
Pressure Port Check Valve Pressure N/A
Indicator Lights Yes
Body Material Gray Iron
Manual Override Plain Override
Solenoid Energization Code None
AC/DC DC
Leakage Standard Performance
Spool Shift Timing N/A
Cycle Rate [Max] N/A
Rated Flow [Max] 20 gal/min
Manual Override Option Code None
Port T Code 7
Mounting Subplate/Manifold Mount
Operation Solenoid Operated
Port Restrictor Plug Code None
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs None
Solenoid Code G
Crossover All Ports Blocked
Coil Type Code F
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Solenoid Indicator Lights Code L
Electrical Connector Code T
Voltage & Frequency 12 VDC
Mechanical Options None
Spool Indicator Switch Code None
Pilot/Drain None
Response Type Standard Response
No. of Stages Single Stage
EN Code None
Compatible Fluids Petroleum Oil
Spool Code 2
Model No. DG4V-3-2C-M-FTWL-G7-60
Watt Rating 30 W
Port T Pressure Rating 3000 psi
NFPA Size D03
Temperature Range [Min] -4 °F
Seal Material Buna-N
Electrical Options None
Electrical Connection Wired Terminal Block
Center Position All Ports Blocked
Actuation Identification Solenoid A, Solenoid B
Reducer Module No
Response Time 28 to 45 ms
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Solenoid Double
Spool Spring Arrangement Code C
Valve Type High-Performance
Temperature Range [Max] 158 °F
Weight 5.0 LB