Vickers D03 Solenoid Valve

02-147417

Vickers D03 Solenoid Valve
Item #102039932
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Multi-fluid capability without the need to change seals
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
Function Code 6
Valve Type High-Performance
Compatible Fluids Petroleum Oil
Spool Code 6
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Temperature Range [Max] 158 °F
Body Material Gray Iron
Solenoid Energization Code None
Electrical Connection Wired Terminal Block
NFPA Size D03
Electrical Options None
Housing Code W
Response Type Standard Response
Seal Material Buna-N
Solenoid Indicator Lights Code L
Electrical Connector Code T
Coil Rating Code B
Model No. DG4V-3-6B-M-FTWL-B6-60
Manual Override Option Code None
Crossover P Blocked, A or B to T
No. of Stages Single Stage
Port T Code 6
Spool Shift Timing N/A
Mechanical Options None
Tank Port Rating 3046
Indicator Lights Yes
Surge Suppressor/Damper Code None
Design No. 60
Leakage Standard Performance
Pressure [Max] 5000 psi
Pilot/Drain None
Operation Solenoid Operated
Solenoid Code B
Pilot Valve Type N/A
Actuator Type Solenoid
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Indicator Switch Code None
Manual Override Plain Override
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Spring Arrangement Code B
Mounting Subplate/Manifold Mount
Overrides No Overrides
Function 2-Position Spring Offset, End to Center
Cycle Rate [Max] N/A
Pressure Port Check Valve Pressure N/A
Coil Type Code F
Port Restrictor Plug Code None
Port Restrictor Plugs None
EN Code None
Response Time 15 to 23 ms
Temperature Range [Min] -4 °F
AC/DC AC
Solenoid Single
Center Position P Blocked, A & B to T
Performance High Performance
Surge Suppressor/Damper None
Rated Flow [Max] 20 gal/min
Actuation Identification Solenoid B
Port T Pressure Rating 3000 psi
Weight 5.0 LB