Vickers D03 Solenoid Valve

02-147424

Vickers D03 Solenoid Valve
Item #102039440
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Voltage & Frequency 24 VDC
Pressure Port Check Valve Pressure N/A
Overrides No Overrides
Performance High Performance
AC/DC DC
Temperature Range [Min] -4 °F
Spool Indicator Switch Code None
Coil Rating Code HL
Coil Type ISO 4400
Compatible Fluids Petroleum Oil
Mechanical Options None
Spool Shift Timing N/A
Operation Solenoid Operated
Pilot Valve Type N/A
Actuator Type Solenoid
Housing Code None
Temperature Range [Max] 158 °F
Fluid Cleanliness 19/17/14 micron
Solenoid Code HL
Rated Flow [Max] 20 gal/min
Pilot/Drain None
Spool Code 6
Port T Code 7
Tank Port Rating 3046
Coil Type Code U
Cycle Rate [Max] N/A
EN Code None
Surge Suppressor/Damper None
Model No. DG4V 3 6AL M U HL7 60
Electrical Connector Code None
Seal Material Buna-N
Surge Suppressor/Damper Code None
Port Restrictor Plug Code None
NFPA Size D03
Manual Override Plain Override
Mounting Subplate/Manifold Mount
Port Restrictor Plugs None
Port T Pressure Rating 3000 psi
Electrical Connection DIN 43650
Leakage Standard Performance
Watt Rating 18 W
Center Position P Blocked, A & B to T
No. of Stages Single Stage
Indicator Lights No
Spool Spring Arrangement Code A
Response Type Standard Response
Valve Type High-Performance
Solenoid Indicator Lights Code None
Solenoid Single
Actuation Identification Solenoid A
Design No. 60
Manual Override Option Code None
Function 2-Position Spring Offset, Left Hand Build
Solenoid Energization Code None
Body Material Gray Iron
Response Time 28 to 45 ms
Crossover P Blocked, A or B to T
Pressure [Max] 5000 psi
Reducer Module No
Function Code 6
Electrical Options None
Weight 5.0 LB