Vickers D03 Solenoid Valve

02-147445

Vickers D03 Solenoid Valve
Item #102039987
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Body Material Gray Iron
Solenoid Energization Code None
Design No. 60
Indicator Lights Yes
Leakage Standard Performance
Housing Code W
Tank Port Rating 1450
Electrical Connection Wired Terminal Block
Rated Flow [Max] 10 gal/min
Function Code 2
Spool Indicator Switch Code None
AC/DC AC
Spool Code 2
Solenoid Code B
Solenoid Indicator Lights Code L
Overrides No Overrides
Port T Pressure Rating 1500 psi
Model No. DG4V-3S-2A-M-FTWL-B5-60-B10
Valve Type Standard-Duty
Cycle Rate [Max] N/A
Electrical Connector Code T
Operation Solenoid Operated
Electrical Options None
Response Time 18 to 32 ms
Pilot Valve Type N/A
Surge Suppressor/Damper Code None
Port Restrictor Plug Code B10
Temperature Range [Min] -4 °F
Mounting Subplate/Manifold Mount
Temperature Range [Max] 158 °F
Pilot/Drain None
Coil Type Code F
NFPA Size D03
Manual Override Plain Override
Compatible Fluids Petroleum Oil
No. of Stages Single Stage
Solenoid Single
Response Type Standard Response
Spool Spring Arrangement Code A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Pressure N/A
Reducer Module No
Function 2-Position Spring Offset, End to End
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Seal Material Buna-N
Actuator Type Solenoid
Spool Shift Timing N/A
Port T Code 5
Performance Standard Performance
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs 1 mm Diameter - B Port
Mechanical Options None
Surge Suppressor/Damper None
Actuation Identification Solenoid B
Pressure [Max] 5000 psi
Crossover All Ports Blocked
Center Position All Ports Blocked
Coil Rating Code B
EN Code None
Manual Override Option Code None
Weight 5.0 LB