Vickers D03 Solenoid Valve

02-148415

Vickers D03 Solenoid Valve
Item #102038724
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Electrical Connection No Connector
Solenoid Energization Code V
Leakage Standard Performance
Response Time 15 to 23 ms
Pressure Port Check Valve Pressure N/A
Function 3-Position Spring Centered
Coil Type Code F
NFPA Size D03
Seal Material Buna-N
Electrical Options None
Model No. DG4V-3-8C-VM-FW-B6-61-EN21
Surge Suppressor/Damper Code None
Spool Code 8
Center Position P to T, A & B Blocked
Cycle Rate [Max] N/A
EN Code EN21
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Housing Code W
Coil Rating Code B
Design No. 61
Port Restrictor Plugs None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Valve Type N/A
No. of Stages Single Stage
Temperature Range [Max] 158 °F
Reducer Module No
Mounting Subplate/Manifold Mount
Tank Port Rating 3046
Actuator Type Solenoid
Actuation Identification Solenoid A, Solenoid B
Overrides No Overrides
Temperature Range [Min] -4 °F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Connector Code None
Spool Spring Arrangement Code C
Indicator Lights No
Valve Type High-Performance
Solenoid Code B
Pressure [Max] 5000 psi
Manual Override Option Code None
Port T Pressure Rating 3000 psi
Performance High Performance
Mechanical Options None
Spool Shift Timing N/A
AC/DC AC
Body Material Gray Iron
Solenoid Double
Fluid Cleanliness 19/17/14 micron
Response Type Standard Response
Function Code 8
Operation Solenoid Operated
Port T Code 6
Crossover All Ports Open, Restricted
Pilot/Drain None
Rated Flow [Max] 20 gal/min
Surge Suppressor/Damper None
Spool Indicator Switch Code None
Manual Override Plain Override
Solenoid Indicator Lights Code None
Weight 5.0 LB