Vickers D03 Solenoid Valve

02-148415

Vickers D03 Solenoid Valve
Item #102038724
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Temperature Range [Max] 158 °F
Cycle Rate [Max] N/A
Coil Rating Code B
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Center Position P to T, A & B Blocked
Pilot/Drain None
Compatible Fluids Petroleum Oil
AC/DC AC
Valve Type High-Performance
Housing Code W
Design No. 61
EN Code EN21
Manual Override Plain Override
Overrides No Overrides
Performance High Performance
Coil Type Code F
Response Time 15 to 23 ms
Model No. DG4V-3-8C-VM-FW-B6-61-EN21
No. of Stages Single Stage
Pressure Port Check Valve Pressure N/A
Solenoid Energization Code V
Electrical Connection No Connector
Indicator Lights No
Temperature Range [Min] -4 °F
Port Restrictor Plug Code None
Solenoid Code B
Spool Shift Timing N/A
Pilot Valve Type N/A
Mechanical Options None
Electrical Connector Code None
Function 3-Position Spring Centered
Body Material Gray Iron
Port T Pressure Rating 3000 psi
Function Code 8
Tank Port Rating 3046
Response Type Standard Response
Spool Spring Arrangement Code C
Port Restrictor Plugs None
Operation Solenoid Operated
NFPA Size D03
Electrical Options None
Crossover All Ports Open, Restricted
Spool Code 8
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Manual Override Option Code None
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Code 6
Spool Indicator Switch Code None
Solenoid Double
Seal Material Buna-N
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Rated Flow [Max] 20 gal/min
Surge Suppressor/Damper Code None
Surge Suppressor/Damper None
Reducer Module No
Weight 5.0 LB