Skip to content Skip to navigation menu
Vickers by Danfoss02-154935

02-154935

Vickers D07 Solenoid Valve
Item #102039524
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-154935
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Port T Pressure Rating 1450 psi
Port Restrictor Plug Code None
Manual Override Plain Override
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Electrical Options None
Port Restrictor Plugs None
Spool Spring Arrangement Code A
AC/DC AC
Solenoid Energization Code None
Model No. DG5S4-046AL-M-FW-B5-60
Electrical Connector Code None
Surge Suppressor/Damper None
EN Code None
Design No. 60
Manual Override Option Code None
Pilot/Drain External Pilot/Internal Drain
Actuator Type Solenoid
Pressure Port Check Valve Code None
Rated Flow [Max] 60 gal/min
Valve Type Standard-Duty
Operation Solenoid Operated
Center Position P Blocked, A & B to T
Indicator Lights No
Pilot Pressure Code None
Solenoid Single
Overrides Plain Override Solenoid Ends
Pilot Valve Type N/A
Response Type Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Code 6
Spool Control Modification Code None
Pressure [Max] 3000 psi
Electrical Options Code None
Pilot Valve Tank Pressure Rating Code 5
Coil Type Code F
Coil Rating Code B
Pilot Drain Code None
Spool Indicator Switch Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Assembly Code L
Response Type Standard Response
Crossover P Blocked, A or B to T
Mounting Screw Option Code N/A
Tank Port Rating 1450
Electrical Connection No Connector
Mechanical Options Single Solenoid Reverse Assembly
Reducer Module N/A
NFPA Size D07
Function 2-Position Spring Offset
Housing Code W
Weight 15.0 LB