Vickers D03 Solenoid Valve

02-155393

Vickers D03 Solenoid Valve
Item #102038940
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Fluid Cleanliness 19/17/14 micron
Response Time 15 to 23 ms
Mechanical Options None
Solenoid Indicator Lights Code None
Housing Code None
NFPA Size D03
Rated Flow [Max] 20 gal/min
Electrical Connector Code None
Spool Indicator Switch Code None
Surge Suppressor/Damper None
Coil Rating Code B
Electrical Connection DIN 43650
Pressure [Max] 5000 psi
Spool Code 8
Valve Type High-Performance
Actuator Type Solenoid
Response Type Standard Response
Port T Pressure Rating 3000 psi
Pressure Port Check Valve Pressure N/A
Performance High Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Code 6
Solenoid Double
Pilot/Drain None
Electrical Options None
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 158 °F
Coil Type Code U
Model No. DG4V-3-8C-VM-U-B6-61-EN21
EN Code EN21
Pilot Valve Type N/A
Port Restrictor Plug Code None
Port Restrictor Plugs None
Indicator Lights No
No. of Stages Single Stage
Spool Spring Arrangement Code C
Leakage Standard Performance
Seal Material Buna-N
Reducer Module No
Function 3-Position Spring Centered
Manual Override Option Code None
Crossover All Ports Open, Restricted
Mounting Subplate/Manifold Mount
Center Position P to T, A & B Blocked
Design No. 61
Spool Shift Timing N/A
Solenoid Code B
Manual Override Plain Override
Surge Suppressor/Damper Code None
Operation Solenoid Operated
Function Code 8
Overrides No Overrides
Cycle Rate [Max] N/A
Temperature Range [Min] -4 °F
Tank Port Rating 3046
Compatible Fluids Petroleum Oil
Solenoid Energization Code V
Body Material Gray Iron
AC/DC AC
Coil Type ISO 4400
Weight 5.0 LB