Vickers D03 Solenoid Valve

02-155584

Vickers D03 Solenoid Valve
Item #102038435
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Solenoid Indicator Lights Code None
Valve Type Standard-Duty
Coil Rating Code B
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Cycle Rate [Max] N/A
Port Restrictor Plugs None
Response Time 18 to 32 ms
Seal Material Buna-N
Coil Type Code U
Function 2-Position Spring Offset, End to Center
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper None
Solenoid Single
Electrical Options None
Port T Code 5
Mounting Subplate/Manifold Mount
Pilot/Drain None
Coil Type ISO 4400
Surge Suppressor/Damper Code None
Electrical Connection DIN 43650
Pressure Port Check Valve Pressure N/A
Response Type Standard Response
Overrides No Overrides
Design No. 60
Electrical Connector Code None
Spool Code 0
Solenoid Code B
Fluid Cleanliness 19/17/14 micron
AC/DC AC
Pressure [Max] 5000 psi
Actuation Identification Solenoid B
Solenoid Energization Code None
NFPA Size D03
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 1450
Manual Override Option Code None
Spool Spring Arrangement Code B
Leakage Standard Performance
EN Code EN21
Mechanical Options None
Reducer Module No
Rated Flow [Max] 10 gal/min
Pilot Valve Type N/A
Temperature Range [Min] -4 °F
Indicator Lights No
Housing Code None
Manual Override Plain Override
Model No. DG4V-3S-0B-M-U-B5-60-EN21
No. of Stages Single Stage
Actuator Type Solenoid
Spool Shift Timing N/A
Function Code 0
Center Position All Ports Open
Crossover All Ports Open
Performance Standard Performance
Temperature Range [Max] 158 °F
Body Material Gray Iron
Operation Solenoid Operated
Port T Pressure Rating 1500 psi
Weight 5.0 LB