Vickers D03 Solenoid Valve

02-156177

Vickers D03 Solenoid Valve
Item #102039634
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Spool Shift Timing N/A
Fluid Cleanliness 19/17/14 micron
Watt Rating 30 W
Design No. 60
Compatible Fluids Petroleum Oil
Port Restrictor Plug Code None
Spool Spring Arrangement Code N
Function Code 6
Electrical Connector Code PA5
Coil Type Code F
NFPA Size D03
Pilot/Drain None
Surge Suppressor/Damper None
Pilot Valve Type N/A
Tank Port Rating 3046
AC/DC DC
Function 3-Position Detented
Indicator Lights Yes
Reducer Module No
Electrical Connection Five Pin Connector
Mechanical Options None
Coil Rating Code H
Port Restrictor Plugs None
Voltage & Frequency 24 VDC
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Solenoid Code H
Actuator Type Solenoid
Spool Indicator Switch Code None
Housing Code W
Temperature Range [Max] 158 °F
Leakage Standard Performance
Center Position P Blocked, A & B to T
Operation Solenoid Operated
Overrides No Overrides
Spool Code 6
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code L
Valve Type High-Performance
No. of Stages Single Stage
EN Code None
Actuation Identification Solenoid A, Solenoid B
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Model No. DG4V-3-6N-M-FPA5WL-H7-60
Temperature Range [Min] -4 °F
Solenoid Double
Response Type Standard Response
Crossover P Blocked, A or B to T
Rated Flow [Max] 20 gal/min
Manual Override Plain Override
Seal Material Buna-N
Electrical Options None
Performance High Performance
Port T Code 7
Pressure [Max] 5000 psi
Solenoid Energization Code None
Port T Pressure Rating 3000 psi
Response Time 28 to 45 ms
Cycle Rate [Max] N/A
Manual Override Option Code None
Weight 5.0 LB