Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-308508

Vickers D03 Solenoid Valve
Item #102088202
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
NFPA Size D03
Pressure [Max] 5000 psi
Reducer Module No
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Spring Arrangement Code C
Watt Rating 30 W
Temperature Range [Max] 158 °F
Coil Type Code F
Tank Port Rating 3046
Coil Rating Code H
Response Time 28 to 45 ms
Electrical Connector Code None
Function 3-Position Spring Centered
Spool Code 0
Center Position All Ports Open
AC/DC DC
Operation Solenoid Operated
Manual Override Option Code None
Port T Code 7
Indicator Lights No
Surge Suppressor/Damper Code None
Leakage Standard Performance
Rated Flow [Max] 20 gal/min
Actuation Identification Solenoid A, Solenoid B
Mounting Subplate/Manifold Mount
Response Type Standard Response
Design No. 60
Mechanical Options None
Manual Override Plain Override
Solenoid Indicator Lights Code None
Solenoid Double
Crossover All Ports Open
Temperature Range [Min] -4 °F
Electrical Options None
No. of Stages Single Stage
Seal Material Buna-N
EN Code EN21
Pressure Port Check Valve Pressure N/A
Compatible Fluids Petroleum Oil
Spool Shift Timing N/A
Housing Code W
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Actuator Type Solenoid
Surge Suppressor/Damper None
Pilot Valve Type N/A
Model No. DG4V-3-0C-M-FW-H7-60-EN21
Valve Type High-Performance
Function Code 0
Port T Pressure Rating 3000 psi
Solenoid Code H
Overrides No Overrides
Port Restrictor Plugs None
Voltage & Frequency 24 VDC
Pilot/Drain None
Solenoid Energization Code None
Electrical Connection No Connector
Performance High Performance
Spool Indicator Switch Code None
Body Material Gray Iron
Cycle Rate [Max] N/A
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison