Vickers D03 Solenoid Valve

02-309214

Vickers D03 Solenoid Valve
Item #102088990
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position All Ports Blocked
Operation Solenoid Operated
EN Code EN21
Electrical Options None
Port Restrictor Plug Code None
Coil Type Code U
Fluid Cleanliness 19/17/14 micron
Design No. 60
Temperature Range [Min] -4 °F
Reducer Module No
Model No. DG4V-3-2N-M-U-B6-60-EN21
Cycle Rate [Max] N/A
Solenoid Indicator Lights Code None
Housing Code None
Response Time 15 to 23 ms
Spool Indicator Switch Code None
Function 3-Position Detented
Manual Override Plain Override
Port T Pressure Rating 3000 psi
Manual Override Option Code None
Mechanical Options None
Pilot Valve Type N/A
Solenoid Code B
Indicator Lights No
Temperature Range [Max] 158 °F
Voltage & Frequency 110/120 VAC - 50/60 Hz
AC/DC AC
Pilot/Drain None
Function Code 2
Rated Flow [Max] 20 gal/min
Mounting Subplate/Manifold Mount
Leakage Standard Performance
Actuator Type Solenoid
Coil Rating Code B
Tank Port Rating 3046
Electrical Connection DIN 43650
Spool Code 2
Solenoid Double
Pressure Port Check Valve Pressure N/A
Spool Spring Arrangement Code N
Spool Shift Timing N/A
Surge Suppressor/Damper Code None
Seal Material Buna-N
Response Type Standard Response
Solenoid Energization Code None
Pressure [Max] 5000 psi
Port T Code 6
NFPA Size D03
Actuation Identification Solenoid A, Solenoid B
Body Material Gray Iron
Electrical Connector Code None
Port Restrictor Plugs None
Overrides No Overrides
Valve Type High-Performance
Performance High Performance
Coil Type ISO 4400
Crossover All Ports Blocked
Surge Suppressor/Damper None
No. of Stages Single Stage
Compatible Fluids Petroleum Oil
Weight 5.0 LB