Vickers D03 Solenoid Valve

02-311556

Vickers D03 Solenoid Valve
Item #102088184
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Up to 21 gpm at 5,000 psi
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
No. of Stages Single Stage
Electrical Connection DIN 43650
Coil Type Code U
Spool Spring Arrangement Code B
Voltage & Frequency 24 VDC
Port Restrictor Plugs None
Temperature Range [Min] -4 °F
Mounting Subplate/Manifold Mount
Response Time 28 to 45 ms
Manual Override Plain Override
Design No. 61
Pressure Port Check Valve Pressure N/A
Solenoid Code H
Solenoid Indicator Lights Code None
Reducer Module No
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Surge Suppressor/Damper Code None
AC/DC DC
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid A
Model No. DG4V-3-8BL-VM-U-H7-61
Port Restrictor Plug Code None
Overrides No Overrides
Electrical Connector Code None
Watt Rating 30 W
Surge Suppressor/Damper None
Cycle Rate [Max] N/A
Function Code 8
Coil Rating Code H
Function 2-Position Spring Offset, End To Center, Left Hand Build
Response Type Standard Response
Electrical Options None
Mechanical Options None
Pilot/Drain None
Spool Indicator Switch Code None
Body Material Gray Iron
Coil Type ISO 4400
Port T Code 7
NFPA Size D03
Spool Shift Timing N/A
Solenoid Single
Operation Solenoid Operated
Solenoid Energization Code V
Valve Type High-Performance
Crossover All Ports Open, Restricted
Leakage Standard Performance
Spool Code 8
Performance High Performance
Fluid Cleanliness 19/17/14 micron
Center Position P to T, A & B Blocked
Pilot Valve Type N/A
Pressure [Max] 5000 psi
Indicator Lights No
Housing Code None
Manual Override Option Code None
Tank Port Rating 3046
Temperature Range [Max] 158 °F
EN Code None
Port T Pressure Rating 3000 psi
Actuator Type Solenoid
Weight 5.0 LB