Vickers D03 Solenoid Valve

02-318554

Vickers D03 Solenoid Valve
Item #102088155
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 3-Position Spring Centered
Port Restrictor Plugs None
Crossover All Ports Blocked
Manual Override Option Code H
NFPA Size D03
Coil Rating Code B
Housing Code W
Solenoid Double
Indicator Lights No
Response Type Standard Response
Tank Port Rating 1500
Spool Shift Timing N/A
Cycle Rate [Max] N/A
Port T Pressure Rating 1500 psi
Operation Solenoid Operated
Center Position All Ports Blocked
Surge Suppressor/Damper Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Code 5
Spool Indicator Switch Code None
Electrical Options None
AC/DC AC
Spool Spring Arrangement Code C
Electrical Connector Code T
Spool Code 2
Rated Flow [Max] 10.5 gal/min
Function Code 2
Pilot/Drain None
Mechanical Options None
Design No. 60
Pilot Valve Type N/A
Valve Type Standard-Duty
Overrides No Overrides
Solenoid Indicator Lights Code None
EN Code None
Actuator Type Solenoid
Electrical Connection Wired Terminal Block
Surge Suppressor/Damper None
Pressure Port Check Valve Pressure N/A
Seal Material Buna-N
Solenoid Energization Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Pressure [Max] 5075 psi
Solenoid Code B
Coil Type Code F
Reducer Module N/A
Model No. DG4V 3S 2C H M FTW B5 60
Weight 5.0 LB