Vickers D03 Solenoid Valve

02-323452

Vickers D03 Solenoid Valve
Item #102087229
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Shift to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Shift to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
Actuator Type Solenoid
EN Code None
Reducer Module N/A
Seal Material Buna-N
Function Code 2
Surge Suppressor/Damper Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Model No. DG4V 3S 2FL M FTWL B5 60
Surge Suppressor/Damper None
Center Position All Ports Blocked
Electrical Connection Wired Terminal Block
Spool Shift Timing N/A
Coil Rating Code B
Function 2-Position Spring Offset, Shift to Center
Port Restrictor Plugs None
Overrides No Overrides
Indicator Lights Yes
Mechanical Options None
Manual Override Option Code None
Pilot/Drain None
Tank Port Rating 1500
Pressure [Max] 5075 psi
AC/DC AC
Port T Pressure Rating 1500 psi
Solenoid Code B
Spool Code 2
Operation Solenoid Operated
Electrical Options None
Response Type Standard Response
Housing Code W
Valve Type Standard-Duty
Solenoid Single
NFPA Size D03
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code L
Port T Code 5
Rated Flow [Max] 10.5 gal/min
Pilot Valve Type N/A
Crossover All Ports Blocked
Design No. 60
Port Restrictor Plug Code None
Solenoid Energization Code None
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
Coil Type Code F
Cycle Rate [Max] N/A
Spool Spring Arrangement Code FL
Electrical Connector Code T
Weight 5.0 LB