Vickers by Danfoss02-325888

02-325888

Vickers D08 Solenoid Valve
Item #101979724
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-325888
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Standard, QD-style HTD sprockets may not have the torque capacity for the higher rated HT150 belts.
Pilot Valve Type Code S
Seal Material Buna-N
Mechanical Options None
Spool Control Modification Code None
Spool Code 11
Manual Override Option Code None
Function 3-Position Spring Centered
Response Type Code None
No. of Stages Two Stage
Solenoid Indicator Lights Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Actuator Type Solenoid
Design No. 10
Compatible Fluids Petroleum Oil
NFPA Size D08
Coil Rating Code B
Gauge Port SAE-4
Coil Type Code F
Mechanical Options Code None
Surge Suppressor/Damper None
Pilot Drain Code None
Reducer Module No
Electrical Options Code None
Response Type Standard Response
Spool Indicator Switch Code None
Temperature Range [Max] 230 °F
Port T Pressure Rating 5000 psi
Manual Override Plain Override
Pilot Valve Type CETOP 3, Standard Performance
Fluid Cleanliness 19/17/14 micron
Crossover N/A
Port Restrictor Plug Code None
Performance Standard Performance
Pressure [Max] 5000 psi
Electrical Options None
Tank Port Rating 5000
Operation Pilot Operated
Electrical Connection No Connector
Reducer Module Code None
AC/DC AC
Rated Flow [Max] 175 gal/min
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mounting Subplate/Manifold Mount
Electrical Connector Code None
Pressure Port Check Valve Code None
Leakage Standard Performance
Actuation Identification Solenoid A, Solenoid B
Gauge Ports Code None
EN Code None
Housing Code W
Pilot/Drain External Pilot/External Drain
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Body Material Ductile Iron
Solenoid Energization Code None
Valve Type Standard-Duty
Pilot Pressure Code E
Temperature Range [Min] -40 °F
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Spring Arrangement Code C
Indicator Lights No
Model No. DG5V-8-S-11C-E-M-FW-B-10
Solenoid Double
Center Position P & B to T, A Blocked
Surge Suppressor/Damper Code None
Overrides Plain Override Solenoid Ends
Weight 35.0 LB