Vickers by Danfoss02-325898

02-325898

Vickers D08 Solenoid Valve
Item #101971273
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-325898
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Coil Type Code F
Gauge Ports Code None
AC/DC AC
Port T Pressure Rating 5000 psi
Leakage Standard Performance
Pressure [Max] 5000 psi
Solenoid Energization Code None
Pilot Pressure Code None
Model No. DG5V-8-H-2C-T-M-FW-B-10
Mechanical Options Code None
Electrical Options Code None
Port Restrictor Plugs None
Spool Center Condition A Port and Double Offset sensing switch on B Port
Surge Suppressor/Damper None
Pilot Valve Type CETOP 3, High Performance
Body Material Gray Iron
Gauge Port SAE-4
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Code 2
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Spool Spring Arrangement Code C
Response Type Code None
Function 3-Position Spring Centered
Voltage & Frequency 110/120 VAC - 50/60 Hz
Operation Pilot Operated
EN Code None
Pressure Port Check Valve Code None
Electrical Connection No Connector
NFPA Size D08
Spool Control Modification Code None
Indicator Lights No
Housing Code W
No. of Stages Two Stage
Pilot/Drain External Pilot/Internal Drain
Electrical Connector Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
Solenoid Double
Response Type Standard Response
Spool Indicator Switch Code None
Manual Override Plain Override
Solenoid Indicator Lights Code None
Manual Override Option Code None
Pilot Valve Type Code H
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper Code None
Mounting Subplate/Manifold Mount
Mechanical Options None
Reducer Module No
Center Position All Ports Blocked
Port Restrictor Plug Code None
Pilot Drain Code T
Design No. 10
Reducer Module Code None
Tank Port Rating 5000
Electrical Options None
Valve Type Standard-Duty
Compatible Fluids Petroleum Oil
Coil Rating Code B
Crossover All Ports Blocked
Seal Material Buna-N
Fluid Cleanliness 19/17/14 micron
Performance High Performance
Weight 35.0 LB