Vickers by Danfoss02-329225

02-329225

Vickers D08 Solenoid Valve
Item #101977563
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329225
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Coil Rating Code D
Response Type Code None
Pilot Valve Type Code S
Voltage & Frequency 220/240 VAC - 50/60 Hz
Pilot Drain Code T
Pilot Valve Type CETOP 3, Standard Performance
Electrical Options None
Reducer Module N/A
Port T Pressure Rating 5000 psi
Spool Spring Arrangement Code C
Valve Type Standard-Duty
Model No. DG5V-8-S-2C-T-M-U-D-10
Surge Suppressor/Damper Code None
Seal Material Buna-N
Manual Override Option Code None
Tank Port Rating 5000
Spool Code 2
Electrical Connection No Connector
Pressure Port Check Valve Code None
Center Position All Ports Blocked
Mechanical Options Code None
AC/DC AC
Pressure [Max] 5000 psi
Function 3-Position Spring Centered
Indicator Lights No
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Pilot/Drain External Pilot/Internal Drain
Solenoid Energization Code None
Overrides Plain Override Solenoid Ends
Reducer Module Code None
Gauge Port SAE-4
Pilot Pressure Code None
Crossover All Ports Blocked
Mechanical Options None
Operation Pilot Operated
Design No. 10
Coil Type DIN 43650
Rated Flow [Max] 185 gal/min
Response Type Standard Response
Actuator Type Solenoid
NFPA Size D08
Surge Suppressor/Damper None
Manual Override Plain Override
Housing Code None
EN Code None
Coil Type Code U
Spool Control Modification Code None
Solenoid Double
Electrical Connector Code None
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Gauge Ports Code None
Port Restrictor Plugs None
Electrical Options Code None
Weight 35.0 LB