Vickers by Danfoss02-329239

02-329239

Vickers D08 Solenoid Valve
Item #101977649
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329239
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Maintain 5 to 8 Nm (4 to 6 ft lb) maximum torque on valve tube nut
  • over-tightening may cause failure
Gauge Ports Code None
Pilot Valve Type Code S
Pressure Port Check Valve Pressure N/A
Spool Code 2
Solenoid Energization Code None
Coil Type Code F
Manual Override Option Code None
Actuator Type Solenoid
Fluid Cleanliness 20/18/15 micron
Spool Spring Arrangement Code C
Port Restrictor Plug Code None
Body Material Gray Iron
Crossover All Ports Blocked
Pilot Drain Code T
Overrides Plain Override Solenoid Ends
Leakage Standard Performance
Seal Material Buna-N
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 5000
Mechanical Options None
Coil Rating Code B
Mechanical Options Code None
Pressure [Max] 5000 psi
Reducer Module Code None
Manual Override Plain Override
Model No. DG5V-8-S-2C-T-M-FTWL-B-10
Spool Control Modification Code None
Electrical Options None
Indicator Lights Yes
Design No. 10
Pilot Valve Type CETOP 3, Standard Performance
Function 3-Position Spring Centered
Reducer Module No
Pilot/Drain External Pilot/Internal Drain
Housing Code W
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
AC/DC AC
Valve Type Standard-Duty
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Performance Standard Performance
Operation Pilot Operated
No. of Stages Two Stage
Solenoid Indicator Lights Code L
Response Type Standard Response
NFPA Size D08
EN Code None
Mounting Subplate/Manifold Mount
Pilot Pressure Code None
Gauge Port SAE-4
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port T Pressure Rating 5000 psi
Electrical Options Code None
Compatible Fluids Petroleum Oil
Surge Suppressor/Damper None
Response Type Code None
Port Restrictor Plugs None
Electrical Connection Wired Terminal Block
Electrical Connector Code T
Solenoid Double
Pressure Port Check Valve Code None
Center Position All Ports Blocked
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Weight 35.0 LB