Vickers D08 Solenoid Valve
Item #101978003
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329246
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Center Condition A Port and Double Offset sensing switch on B Port
Reducer Module Code None
Manual Override Plain Override
Surge Suppressor/Damper Code None
Surge Suppressor/Damper None
Housing Code W
AC/DC AC
Solenoid Energization Code None
Model No. DG5V-8-S-33C-M-FW-B-10
Seal Material Buna-N
Performance Standard Performance
Port Restrictor Plugs None
Mounting Subplate/Manifold Mount
Mechanical Options Code None
Actuator Type Solenoid
Spool Control Modification Code None
NFPA Size D08
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Overrides Plain Override Solenoid Ends
Center Position P Blocked, A & B to T
Compatible Fluids Petroleum Oil
Spool Indicator Switch Code None
Reducer Module No
Fluid Cleanliness 19/17/14 micron
Function 3-Position Spring Centered
Crossover P Blocked, A or B to T
Body Material Ductile Iron
Tank Port Rating 5000
Solenoid Indicator Lights Code None
Coil Rating Code B
Port T Pressure Rating 5000 psi
Gauge Ports Code None
Manual Override Option Code None
Solenoid Double
Pressure [Max] 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Valve Type Standard-Duty
Gauge Port SAE-4
Electrical Options None
Rated Flow [Max] 175 gal/min
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 230 °F
Spool Spring Arrangement Code C
Pilot Valve Type Code S
Temperature Range [Min] -40 °F
Port Restrictor Plug Code None
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
EN Code None
Pilot Pressure Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot/Drain Internal Pilot/External Drain
Electrical Connector Code None
Mechanical Options None
Leakage Standard Performance
Response Type Code None
Pressure Port Check Valve Pressure N/A
Electrical Options Code None
No. of Stages Two Stage
Spool Code 33
Indicator Lights No
Operation Pilot Operated
Pressure Port Check Valve Code None
Response Type Standard Response
Coil Type Code F
Design No. 10
Pilot Drain Code None
Weight 35.0 LB