Vickers by Danfoss02-329264

02-329264

Vickers D08 Solenoid Valve
Item #102083938
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329264
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Cannot be used in air systems where compressors are lubricated with fire-resistant fluids, such as phosphate ester and di-ester types
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type Code S
Pilot Drain Code None
EN Code None
Port Restrictor Plugs None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
No. of Stages Two Stage
Reducer Module Code None
Compatible Fluids Petroleum Oil
Spool Indicator Switch Code None
Pressure Port Check Valve Code None
Response Type Code None
Tank Port Rating 5000
Indicator Lights Yes
Port T Pressure Rating 5000 psi
Valve Type Standard-Duty
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code L
Surge Suppressor/Damper Code None
Pressure Port Check Valve Pressure N/A
Reducer Module No
Body Material Ductile Iron
Coil Type Code F
Response Type Standard Response
Electrical Options None
AC/DC AC
Spool Spring Arrangement Code C
Rated Flow [Max] 175 gal/min
Coil Rating Code B
Overrides Plain Override Solenoid Ends
Electrical Options Code None
Mechanical Options None
Crossover All Ports Open, Restricted
Gauge Port SAE-4
Function 3-Position Spring Centered
Spool Control Modification Code None
NFPA Size D08
Fluid Cleanliness 19/17/14 micron
Electrical Connection Wired Terminal Block
Solenoid Double
Actuator Type Solenoid
Center Position P to T, A & B Blocked
Manual Override Option Code None
Performance Standard Performance
Port Restrictor Plug Code None
Operation Pilot Operated
Manual Override Plain Override
Solenoid Energization Code V
Temperature Range [Max] 230 °F
Mechanical Options Code None
Pilot/Drain External Pilot/External Drain
Pressure [Max] 5000 psi
Pilot Valve Type CETOP 3, Standard Performance
Leakage Standard Performance
Pilot Pressure Code E
Temperature Range [Min] -40 °F
Mounting Subplate/Manifold Mount
Actuation Identification Solenoid A, Solenoid B
Model No. DG5V-8-S-8C-E-VM-FTWL-B-10
Housing Code W
Design No. 10
Spool Code 8
Gauge Ports Code None
Surge Suppressor/Damper None
Electrical Connector Code T
Seal Material Buna-N
Weight 35.0 LB