Vickers by Danfoss02-329264

02-329264

Vickers D08 Solenoid Valve
Item #102083938
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329264
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Cannot be used in air systems where compressors are lubricated with fire-resistant fluids, such as phosphate ester and di-ester types
Port Restrictor Plug Code None
AC/DC AC
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Electrical Connector Code T
Electrical Options Code None
Center Position P to T, A & B Blocked
Solenoid Energization Code V
Performance Standard Performance
Actuator Type Solenoid
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Crossover All Ports Open, Restricted
Operation Pilot Operated
Spool Spring Arrangement Code C
Solenoid Indicator Lights Code L
Port Restrictor Plugs None
Spool Control Modification Code None
Pressure Port Check Valve Code None
Coil Type Code F
Gauge Port SAE-4
Body Material Ductile Iron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Housing Code W
Indicator Lights Yes
No. of Stages Two Stage
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Compatible Fluids Petroleum Oil
Overrides Plain Override Solenoid Ends
Reducer Module No
Design No. 10
Mechanical Options None
Response Type Code None
Pilot/Drain External Pilot/External Drain
Temperature Range [Max] 230 °F
Pilot Drain Code None
Coil Rating Code B
Surge Suppressor/Damper None
Seal Material Buna-N
Response Type Standard Response
EN Code None
Surge Suppressor/Damper Code None
Gauge Ports Code None
Electrical Connection Wired Terminal Block
Electrical Options None
Reducer Module Code None
Function 3-Position Spring Centered
Tank Port Rating 5000
Actuation Identification Solenoid A, Solenoid B
Fluid Cleanliness 19/17/14 micron
Mounting Subplate/Manifold Mount
Solenoid Double
Model No. DG5V-8-S-8C-E-VM-FTWL-B-10
Pilot Pressure Code E
Manual Override Option Code None
NFPA Size D08
Port T Pressure Rating 5000 psi
Leakage Standard Performance
Rated Flow [Max] 175 gal/min
Manual Override Plain Override
Mechanical Options Code None
Pilot Valve Type Code S
Pilot Valve Type CETOP 3, Standard Performance
Temperature Range [Min] -40 °F
Spool Code 8
Spool Indicator Switch Code None
Weight 35.0 LB